CareerExamPro

HIMSS Certified Professional in Healthcare IT (CPHIMS) practice test

24 practice questions for this exam, each with a full explanation and cited rule or blueprint reference.

Start practising

CPHIMS, RHIA, CHPC (HIPAA) & CRCR: practice drill

10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.

Timed mock exam

24 questions in 29 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.

Practice tests that prepare you for this exam

Practise by topic

About this exam

Agency / Issuer
HIMSS
Region
Global / Online

Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.

Sample questions

A medical group contracts with a cloud service provider (CSP) to store encrypted EHR backups while the clinic retains exclusive control of the decryption keys. The CSP in turn hires a third-party data-center subcontractor to manage those backup servers. Under the HITECH Act, HIPAA Omnibus Rule, and HHS Cloud Computing Guidance, how do Business Associate rules apply?

  1. Neither the CSP nor its subcontractor is a Business Associate because encrypted 'no-view' storage qualifies for the HIPAA conduit exception.
  2. Both the CSP and subcontractor are directly liable Business Associates; the clinic signs a BAA with the CSP, which signs a downstream BAA.
  3. The medical group must execute separate direct Business Associate Agreements with both the CSP and every downstream subcontractor in the vendor's hosting supply chain.
  4. Only the primary CSP is subject to HIPAA Security Rule enforcement, whereas downstream subcontractors are regulated solely by state commercial contract law.
Show the answer

B. Both the CSP and subcontractor are directly liable Business Associates; the clinic signs a BAA with the CSP, which signs a downstream BAA.

Under 45 CFR 160.103, 164.502(e), and HHS Cloud Computing Guidance, a CSP that persistently maintains ePHI on behalf of a covered entity is a Business Associate even when storing encrypted ('no-view') data without holding the decryption key—persistent storage does not qualify for the narrow transient-transmission conduit exception. Under the HITECH Act and 2013 Omnibus Rule, downstream subcontractors that handle ePHI are also directly liable Business Associates, and BAA obligations flow down from the primary BA to its subcontractor.

Reference: 45 CFR 160.103, 164.502(e), 164.308(b) & HHS Guidance on HIPAA and Cloud Computing

An interface analyst is configuring HL7 v2.x pipe-delimited feeds between an acute care hospital's EHR and its laboratory information system (LIS). Which pairing accurately distinguishes the message event type used when a patient is admitted from the message event type used to transmit completed lab values back to the EHR?

  1. ORU^R01 transmits inpatient admission demographics in PV1 segments, while ADT^A01 returns structured lab results in OBX segments.
  2. ADT^A04 transmits inpatient admission events using FHIR JSON payloads, while ORM^O01 returns finalized chemistry observations.
  3. ADT^A01 conveys inpatient admission demographics (MSH, PID, PV1), while ORU^R01 returns lab results (OBR, OBX).
  4. SIU^S12 transmits inpatient admission demographics across pipe-delimited segments, while DFT^P03 returns automated laboratory results.
Show the answer

C. ADT^A01 conveys inpatient admission demographics (MSH, PID, PV1), while ORU^R01 returns lab results (OBR, OBX).

In HL7 v2.x pipe-delimited messaging, ADT^A01 (Admit/Visit Notification) conveys inpatient admission and demographic data via MSH, PID, and PV1 segments, whereas ORU^R01 (Unsolicited Observation Result) delivers completed diagnostic and laboratory results using OBR (Observation Request) and OBX (Observation/Result) segments. ORM^O01 is used for orders, SIU^S12 for scheduling, and DFT^P03 for financial charges.

Reference: HL7 v2.5.1 Messaging Standard — Chapters 3 (ADT) & 7 (ORU); HIMSS CPHIMS

During an internal compliance review, a hospital IT manager states that because encryption of ePHI at rest (45 CFR 164.312(a)(2)(iv)) is an 'addressable' technical safeguard, the hospital may skip encrypting clinician laptops without documentation, and may postpone its enterprise Security Risk Analysis until after next year's EHR upgrade. Why is this approach noncompliant?

  1. Encryption at rest is a Required specification with zero exceptions under HIPAA, whereas Risk Analysis is an addressable safeguard that may be deferred during upgrades.
  2. Addressable specifications apply only to Business Associates rather than hospitals, whereas Risk Analysis is required only after a reportable data breach occurs.
  3. Both encryption and Risk Analysis are voluntary best practices recommended by NIST rather than enforceable standards under the HIPAA Security Rule.
  4. Risk Analysis is a Required Administrative Safeguard (164.308(a)(1)), and addressable safeguards require implementation or documented alternatives.
Show the answer

D. Risk Analysis is a Required Administrative Safeguard (164.308(a)(1)), and addressable safeguards require implementation or documented alternatives.

Under 45 CFR 164.308(a)(1)(ii)(A), conducting an accurate and thorough Risk Analysis of potential risks and vulnerabilities to the confidentiality, integrity, and availability of all ePHI is a foundational Required Administrative Safeguard. Moreover, under 45 CFR 164.306(d)(3), 'addressable' does NOT mean optional: a covered entity must implement the specification if reasonable and appropriate, or else document why it is not reasonable and appropriate and implement an equivalent alternative measure if reasonable and appropriate.

Reference: HIPAA Security Rule — 45 CFR 164.306(d), 164.308(a)(1)(ii)(A) & 164.312(a)(2)(iv)

Taking this exam soon?

Tell us which exam domains or calculation drills you want more practice on.

Other Healthcare IT, Compliance & HIM exams